An automatic pump filter installed in the water inlet socket automatically protects the pump from sand and gravel contaminants. In addition, these filters protect the entire water cycle, including cooling towers and thermal converters, from contamination. The entire water system and the pump do not stop working, which prolongs their service life and ensures efficient water supply.
The special design of the pump protects the entire system and pump from organic and inorganic contaminants. An automatic pump filter can be connected to the pump outlet. This system is connected under water (pool, river, water tank, etc.).
Operation principle
When water enters the filter, organic and inorganic fragments and solid particles are trapped. In this way, the pump and other equipment are protected against clogging and damage, water circulation efficiency is improved, energy and maintenance costs are reduced.
The filter has a self-cleaning function: manually adjustable valve (12), adjustable flushing current with hydraulic actuator (13) and self-cleaning component (4).
- Pump filter
- Adapter
- Manual filter
- Self-cleaning component
- Sprayer
- Filter inner surface
- Pump outlet
- Rinse aid outlet
- Rinse aid inlet
- Pressure sensor
- Check valve
- Manually controlled valve
- Hydraulic drive
Applications
- Industry: protection of swimming pool pumps, circulating fluid pumps, sewage pumps, etc.
- Housing and public utilities: protection of pumping stations pumps, sewage treatment pumps, etc.
- Agriculture: protection of pumps for lake, river and sea water.
Technical data
Model |
Outlet DN, mm |
Diameter Ø DN, mm |
Height, H |
Water flow at 1.2 mm, m3/h |
Water flow at 2.5 mm, m3/h |
Weight, kg |
CAF 1004 |
100 |
560 |
52 |
80 |
100 |
25 |
CAF 1006 |
150 |
560 |
67 |
150 |
190 |
35 |
CAF 1008 |
200 |
560 |
87 |
300 |
380 |
45 |
CAF 1010 |
250 |
830 |
79 |
500 |
630 |
60 |
CAF 1012 |
300 |
830 |
79 |
700 |
880 |
70 |
CAF 1014 |
350 |
1160 |
1029 |
1100 |
1000 |
120 |
CAF 1016 |
400 |
1160 |
1029 |
1400 |
1380 |
130 |
CAF 1018 |
450 |
1375 |
1032 |
1750 |
2180 |
190 |
CAF 1020 |
500 |
1375 |
1032 |
2200 |
2750 |
210 |
Minimum operating pressure: 0.15 Mpa
Filter material: 304 stainless steel
Wash water consumption
Filter selection
When selecting the automatic pump filter, it is important to pay attention to the following:
Pump water flow rate;
- Pump inlet diameter;
- The number of solid particles;
- Accuracy;
- Pump operating pressure;
- Installation location.
Installation